Methane-Only. Infrared Spectroscopy. ppm×m Output. Real-Time RC & UgCS.
The Laser Falcon 2 is built around a single detection principle: Infrared Absorption Spectroscopy at 1.65 μm, sensitive exclusively to methane. The Class 3R eye-safe laser emits light along the detection path, reflects it back to the sensor, and compares outgoing and incoming signals against a built-in reference cell — if methane is present, the absorbed signal is detected and concentration is calculated in ppm×m. Because the system is sensitive only to methane, false readings from other gases are physically impossible — delivering reliable, actionable detection data without noise from non-target compounds. Results are transmitted instantly to the drone pilot's RC and to UgCS for real-time monitoring and data logging during aerial survey missions.
Learn More +
El Laser Falcon 2 es sensible únicamente al metano, por lo que no se pueden producir lecturas falsas de otros gases. Es un láser de clase 3R seguro para la vista.
El concepto se basa en la espectroscopia de absorción infrarroja.
- El láser emite luz (rango espectral de 1,65 μm), que se refleja y es captada por el sensor.
- Las señales entrantes y salientes se comparan con la celda de referencia incorporada.
- Si hay metano a lo largo de la trayectoria del láser, la luz láser se absorbe parcialmente. Un algoritmo calcula la concentración de gas en ppm × m (partes por millón multiplicadas por metro).
- El valor se transfiere instantáneamente al control remoto (RC) del piloto del dron y al UgCS software.
Tenga en cuenta que se requieren componentes y software adicionales para usar este sensor con drones. Recibirá una lista completa de los elementos necesarios al responder a su solicitud de presupuesto.
- Código SA: 90271010 (Aparato electrónico de análisis de gases o humos)